DESCRIPTION
DTC No. | Detection Item |
DTC Detection Condition | Trouble Area |
MIL | Warning Indicate |
P0E5111 | DC/DC Converter Current Sensor Circuit Short to Ground |
Short to GND detected in reactor current sensor circuit (1 trip detection logic) |
Inverter with converter assembly |
Comes on | Master Warning Light:
Comes on | P0E5115 |
DC/DC Converter Current Sensor Circuit Short to Battery or Open |
Open or short to +B detected in reactor current sensor circuit
(1 trip detection logic) |
Inverter with converter assembly |
Comes on | Master Warning Light:
Comes on | P0E511F |
DC/DC Converter Current Sensor Circuit Intermittent |
Short
to GND, open or short to ground detected in reactor current sensor
circuit when DTC P0C7917, P0D3319, P1C5D19 or P1C5F19 is stored. (1 trip detection logic) |
Inverter with converter assembly |
Does not come on | Master Warning Light:
Does not come on | Related Data List
DTC No. | Data List |
P0E5111 P0E5115 P0E511F |
Inverter Input Current | MONITOR DESCRIPTION
If
the motor generator control ECU detects an open or short in the DC/DC
converter current sensor circuit, it will illuminate the MIL and store a
DTC. MONITOR STRATEGY
Related DTCs | P0E53 (INF P0E5111): DC/DC Converter Current Sensor Range check (Low voltage)
P0E54 (INF P0E5115): DC/DC Converter Current Sensor Range check (High voltage) |
Required sensors/components | DC/DC converter current sensor |
Frequency of operation | Continuous |
Duration | TMC's intellectual property |
MIL operation | Immediately |
Sequence of operation | None | TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored |
TMC's intellectual property | Other conditions belong to TMC's intellectual property |
- | TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property |
- | COMPONENT OPERATING RANGE
Motor generator control ECU | DTC P0E53 (INF P0E5111) is not detected
DTC P0E54 (INF P0E5115) is not detected | CONFIRMATION DRIVING PATTERN
HINT:
- After repair has been completed, clear the DTC and then check that the
vehicle has returned to normal by performing the following All Readiness
check procedure.
Click here
- When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG) and turn the Techstream on.
- Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
- Turn the power switch off and wait for 2 minutes or more.
- Turn the power switch on (IG) and turn the Techstream on.
- With power switch on (IG) and wait for 5 seconds or more. [*1]
HINT:
[*1]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
- Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
- Check the DTC judgment result.
HINT:
- If the judgment result shows NORMAL, the system is normal.
- If the judgment result shows ABNORMAL, the system has a malfunction.
- If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.
CAUTION / NOTICE / HINT
CAUTION:
NOTICE: After
turning the power switch off, waiting time may be required before
disconnecting the cable from the negative (-) auxiliary battery
terminal. Therefore, make sure to read the disconnecting the cable from
the negative (-) auxiliary battery terminal notices before proceeding
with work. Click here PROCEDURE
1. |
REPLACE INVERTER WITH CONVERTER ASSEMBLY |
Click here
NEXT |
| COMPLETED | |