DTC No. | Detection Item |
DTC Detection Condition | Trouble Area |
MIL | Warning Indicate |
P06B01C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly |
Comes on | Master Warning Light:
Comes on |
P06D61C |
Generator Control Module Offset Power Circuit Voltage Out of Range |
Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly |
Comes on | Master Warning Light:
Comes on |
P0A1A47 |
Generator Control Module Watchdog / Safety μC Failure |
Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly |
Comes on | Master Warning Light:
Comes on |
P0A1A49 |
Generator Control Module Internal Electronic Failure |
Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly |
Comes on | Master Warning Light:
Comes on |
P1C2A1C |
Generator A/D Converter Circuit Circuit Voltage Out of Range |
Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly |
Comes on | Master Warning Light:
Comes on |
P1C2A49 |
Generator A/D Converter Circuit Internal Electronic Failure |
Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly |
Comes on | Master Warning Light:
Comes on |
P1C2B1C |
Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range |
Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly |
Comes on | Master Warning Light:
Comes on |
P1C2B49 |
Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure |
Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly |
Comes on | Master Warning Light:
Comes on |
P1C601F |
Generator Control Module Position Sensor REF Power Source Circuit Intermittent |
Motor generator control ECU internal malfunction detected when DTC P0C7917, P0D3319, P1C5D19 or P1C5F19 is stored.
(1 trip detection logic) |
Inverter with converter assembly |
Does not come on | Master Warning Light:
Does not come on |
P1C621F | Generator Control Module Offset Power Circuit Intermittent |
Motor generator control ECU internal malfunction detected when DTC P0C7917, P0D3319, P1C5D19 or P1C5F19 is stored.
(1 trip detection logic) |
Inverter with converter assembly |
Does not come on | Master Warning Light:
Does not come on |
P313383 | Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect |
Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly |
Comes on | Master Warning Light:
Comes on |
P313386 |
Communication Error from Generator to Drive Motor "A" Signal Invalid |
Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly |
Comes on | Master Warning Light:
Comes on |
P313387 |
Communication Error from Generator to Drive Motor "A" Missing Message |
Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly |
Comes on | Master Warning Light:
Comes on |
P313483 |
Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect |
Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly |
Comes on | Master Warning Light:
Comes on |
P313486 |
Communication Error from Drive Motor "A" to Generator Signal Invalid |
Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly |
Comes on | Master Warning Light:
Comes on |
P313487 |
Communication Error from Drive Motor "A" to Generator Missing Message |
Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly |
Comes on | Master Warning Light:
Comes on |