DATA LIST / ACTIVE TEST ACTIVE TEST HINT: Using the Techstream to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests. (a) Connect the Techstream to the DLC3. (b) Turn the power switch on (IG). (c) Turn the Techstream on. (d) Enter the following menus: Body Electrical / Air Conditioner / Active Test. (e) Perform the Active Test according to the display on the Techstream. Body Electrical > Air Conditioner > Active Test
|
Toyota Avalon (XX50) 2019-2022 Service & Repair Manual > Dynamic Radar Cruise Control System(for Gasoline Model): Fail-safe Chart
FAIL-SAFE CHART HINT: If any of the following auto cancel conditions are detected while the dynamic radar cruise control system is controlling vehicle speed, the system clears the stored vehicle speed and cancels control of vehicle speed by the dynamic radar cruise control system. Automatic Cancel C ...