DESCRIPTION Refer to the description for DTC P0A001C.
Click here
DTC No. | Detection Item |
DTC Detection Condition | Trouble Area |
MIL | Warning Indicate |
P0A0011 | Motor Electronics Coolant Temperature Sensor Circuit Short to Ground |
Short to ground detected in HV coolant temperature sensor circuit
(1 trip detection logic) |
Inverter with converter assembly |
Comes on | Master Warning Light:
Comes on | P0A0015 |
Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open |
Open or short to +B detected in HV coolant temperature sensor circuit
(1 trip detection logic) |
Inverter with converter assembly |
Comes on | Master Warning Light:
Comes on | Related Data List
DTC No. | Data List |
P0A0011 | Inverter Coolant Temperature |
P0A0015 | MONITOR DESCRIPTION
If
the motor generator control ECU detects a malfunction in the HV coolant
temperature sensor it will illuminate the MIL and store a DTC. MONITOR STRATEGY
Related DTCs | P0A02 (INF P0A0011): Motor Electronics Coolant Temperature Sensor Range check (Low voltage)
P0A03 (INF P0A0015): Motor Electronics Coolant Temperature Sensor Range check (High voltage) |
Required sensors/components | HV coolant temperature sensor |
Frequency of operation | Continuous |
Duration | TMC's intellectual property |
MIL operation | Immediately |
Sequence of operation | None | TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored |
TMC's intellectual property | Other conditions belong to TMC's intellectual property |
- | TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property |
- | COMPONENT OPERATING RANGE
Motor generator control ECU | DTC P0A02 (INF P0A0011) is not detected
DTC P0A03 (INF P0A0015) is not detected | CONFIRMATION DRIVING PATTERN
HINT:
- After repair has been completed, clear the DTC and then check that the
vehicle has returned to normal by performing the following All Readiness
check procedure.
Click here
- When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG) and turn the Techstream on.
- Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
- Turn the power switch off and wait for 2 minutes or more.
- Turn the power switch on (IG) and turn the Techstream on.
- With power switch on (IG) and wait for 5 seconds or more. [*1]
HINT:
[*1]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
- Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
- Check the DTC judgment result.
HINT:
- If the judgment result shows NORMAL, the system is normal.
- If the judgment result shows ABNORMAL, the system has a malfunction.
- If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.
CAUTION / NOTICE / HINT HINT: After
the repair, clear the DTCs. If the value of Data List item "Inverter
Coolant Temperature" is not abnormal (110°C (230°F) or -40°C (-40°F))
when the power switch is turned on (IG), the condition is judged as
normal. (If DTC P0A0011 is output, 110°C (230°F) will be displayed and if DTC P0A0015 is output, -40°C (-40°F) will be displayed.) PROCEDURE
1. |
REPLACE INVERTER WITH CONVERTER ASSEMBLY |
Click here
NEXT |
| COMPLETED | |