Toyota Avalon (XX50) 2019-2022 Service & Repair Manual: Installation

INSTALLATION

CAUTION / NOTICE / HINT

NOTICE:

This procedure includes the installation of small-head bolts. Refer to Small-Head Bolts of Basic Repair Hint to identify the small-head bolts.

Click here

PROCEDURE

1. INSTALL WATER INLET WITH THERMOSTAT SUB-ASSEMBLY

(a) Install a new gasket to the water inlet with thermostat sub-assembly.

HINT:

Be sure to clean the contact surfaces.

(b) Using an 8 mm socket wrench, install the water inlet with thermostat sub-assembly with the 2 bolts.

Torque:

10 N·m {102 kgf·cm, 7 ft·lbf}

(c) Connect the No. 7 water by-pass hose to the water inlet with thermostat sub-assembly and slide the clip to secure it.

(d) Connect the water inlet with thermostat sub-assembly connector.

2. CONNECT NO. 2 RADIATOR HOSE

Click here

3. ADD ENGINE COOLANT (for Engine)

Click here

4. INSPECT FOR COOLANT LEAK (for Engine)

Click here

    Inspection

    Removal

    See More:

    Toyota Avalon (XX50) 2019-2022 Service & Repair Manual > Power Window Regulator Motor(for Front Door): Installation
    INSTALLATION CAUTION / NOTICE / HINT HINT: Use the same procedure for the RH side and LH side. The following procedure is for the LH side. PROCEDURE 1. PRECAUTION NOTICE: After turning the engine switch (for Gasoline Model) or power switch (for HV Model) off, waiting time may be required before disc ...