1. INSPECT HV BATTERY JUNCTION BLOCK ASSEMBLY

(a) Inspect SMRB:

(1) Measure the resistance according to the value(s) in the table below.

*a

Component without harness connected

(HV Battery Junction Block Assembly)

-

-

Standard Resistance:

Tester Connection

Condition

Specified Condition

y5-1 (+) - S2-1 (CBI)

Auxiliary battery voltage not applied between terminals K18-1 (SMRB) and K18-3 (GND)

10 kΩ or higher

Auxiliary battery voltage applied between terminals K18-1 (SMRB) and K18-3 (GND)

Below 1 Ω

(2) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

K18-1 (SMRB) - K18-3 (GND)

-40 to 80°C (-40 to 176°F)

25.0 to 59.0 Ω

If the result is not as specified, replace the HV battery junction block assembly.

(b) Inspect SMRG:

(1) Measure the resistance according to the value(s) in the table below.

*a

Component without harness connected

(HV Battery Junction Block Assembly)

-

-

Standard Resistance:

Tester Connection

Condition

Specified Condition

y3-1 (-) - S3-1 (CEI)

Auxiliary battery voltage not applied between terminals K18-4 (SMRG) and K18-3 (GND)

10 kΩ or higher

Auxiliary battery voltage applied between terminals K18-4 (SMRG) and K18-3 (GND)

Below 1 Ω

(2) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

K18-4 (SMRG) - K18-3 (GND)

-40 to 80°C (-40 to 176°F)

25.0 to 59.0 Ω

If the result is not as specified, replace the HV battery junction block assembly.

(c) Inspect SMRP:

(1) Measure the resistance according to the value(s) in the table below.

*a

Component without harness connected

(HV Battery Junction Block Assembly)

-

-

Standard Resistance:

Tester Connection

Condition

Specified Condition

y3-1 (-) - S3-1 (CEI)

Auxiliary battery voltage not applied between terminals K18-2 (SMRP) and K18-3 (GND)

10 kΩ or higher

Auxiliary battery voltage applied between terminals K18-2 (SMRP) and K18-3 (GND)

24.3 to 29.7 Ω

(2) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

K18-2 (SMRP) - K18-3 (GND)

-40 to 80°C (-40 to 176°F)

140 to 290 Ω

If the result is not as specified, replace the HV battery junction block assembly.

    Components

    Installation

    See More:

    Toyota Avalon (XX50) 2019-2022 Service & Repair Manual > Lane Departure Alert System (w/ Steering Control)(for Hv Model): Data List / Active Test
    DATA LIST / ACTIVE TEST DATA LIST NOTICE: In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not. HINT: Using the Techstream to read the Data List allows the values or states of ...

    Toyota Avalon (XX50) 2019-2022 Owners Manual

    Toyota Avalon (XX50) 2019-2022 Service & Repair Manual

    © 2024 Copyright www.tavalon.net
    0.0161