Toyota Avalon Service & Repair Manual: Hybrid/EV Battery System Discharge Time Too Long (P0C7600)

Toyota Avalon Service & Repair Manual / Engine / Hybrid / Battery Control / Hybrid Control System / Hybrid/EV Battery System Discharge Time Too Long (P0C7600)

DTC SUMMARY

MALFUNCTION DESCRIPTION

When the power switch is turned from on (READY) to off, the hybrid vehicle control ECU detect that the high-voltage capacitor inside the inverter with converter assembly is not discharged.

The cause of this malfunction may be one of the following:

Inverter voltage sensor (VH) internal circuit malfunction
  • Voltage sensor (VH) malfunction
  • Motor generator control ECU (MG ECU) malfunction
  • Communication (wire harness) malfunction
High voltage system malfunction
  • Inverter with converter assembly malfunction
Shutdown signal circuit malfunction
  • Hybrid vehicle control ECU malfunction
  • Wire harness malfunction
  • Inverter with converter assembly malfunction

DESCRIPTION

For a description of the inverter.

Click here

DTC No.

Detection Item

DTC Detection Condition

Trouble Area

MIL

Warning Indicate

P0C7600

Hybrid/EV Battery System Discharge Time Too Long

The inverter voltage (VH) does not drop during discharge.

(Discharge: Offsetting of the residual pressure in the high-voltage side after power switch is turned off)

(1 trip detection logic)

  • Inverter with converter assembly
  • Wire harness or connector
  • Hybrid vehicle control ECU

Does not come on

Master Warning Light:

Comes on

HINT:

When the power switch is turned from on (READY) to off, the MG ECU discharges voltage stored in the inverter by allowing current to flow to motor (MG2) without generating torque. When the vehicle is normal, VH voltage becomes approximately 0 V after discharging. If VH voltage exceeds a specified value, this DTC is stored.

Related Data List

DTC No.

Data List

P0C7600

VH-Voltage after Boosting

CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click here

  1. Connect the Techstream to the DLC3.
  2. Turn the power switch on (IG) and turn the Techstream on.
  3. Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
  4. Turn the power switch off and wait for 2 minutes or more.
  5. Turn the power switch on (READY) and wait for 30 seconds or more.
  6. Turn the power switch off and wait for 2 minutes or more.
  7. Turn the power switch on (IG) and turn the Techstream on.
  8. Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
  9. Check the DTC judgment result.

    HINT:

    • If the judgment result shows NORMAL, the system is normal.
    • If the judgment result shows ABNORMAL, the system has a malfunction.
    • If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.

WIRING DIAGRAM

Refer to the wiring diagram for the shut down signal circuit.

Click here

CAUTION / NOTICE / HINT

CAUTION:

  • Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
    • Inspecting the high-voltage system
    • Disconnecting the low voltage connector of the inverter with converter assembly
    • Disconnecting the low voltage connector of the HV battery
  • To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
  • After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  • After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

    Click here

    HINT:

    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

    *a

    Without waiting for 10 minutes

NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click here

PROCEDURE

1.

CHECK DTC OUTPUT (HYBRID CONTROL, MOTOR GENERATOR)

(a) Connect the Techstream to the DLC3.

(b) Turn the power switch on (IG).

(c) Enter the following menus: Powertrain / Hybrid Control and Motor Generator / Trouble Codes.

(d) Check for DTCs.

Powertrain > Hybrid Control > Trouble Codes Powertrain > Motor Generator > Trouble Codes

Result

Proceed to

P0C7600 only is output, or DTCs except the ones in the table below are also output.

A

DTCs of hybrid control system in the tables below are output.

B

DTCs of motor generator control system in the tables below are output.

C

Malfunction Content

System

Relevant DTC

Microcomputer malfunction

Hybrid control system

P060647

Hybrid/EV Powertrain Control Module Processor Watchdog / Safety MCU Failure

P060687

Hybrid/EV Powertrain Control Module Processor to Monitoring Processor Missing Message

P060A47

Hybrid/EV Powertrain Control Module Monitoring Processor Watchdog / Safety MCU Failure

P060A87

Hybrid/EV Powertrain Control Module Processor from Monitoring Processor Missing Message

P0A1B49

Drive Motor "A" Control Module Internal Electronic Failure

P1C9E9F

Hybrid/EV System Reset Stuck Off

Motor generator control system

P0A1B1F

Generator Control Module Circuit Intermittent

P0A1A47

Generator Control Module Watchdog / Safety μC Failure

P0A1A49

Generator Control Module Internal Electronic Failure

P1C2A1C

Generator A/D Converter Circuit Circuit Voltage Out of Range

P1C2A49

Generator A/D Converter Circuit Internal Electronic Failure

P1C2B1C

Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range

P1C2B49

Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure

P1CAC49

Generator Position Sensor Internal Electronic Failure

P1CAD49

Drive Motor "A" Position Sensor Internal Electronic Failure

P1CAF38

Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect

P1CB038

Drive Motor "A" Position Sensor REF Signal Frequency Incorrect

P313383

Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect

P313386

Communication Error from Generator to Drive Motor "A" Signal Invalid

P313387

Communication Error from Generator to Drive Motor "A" Missing Message

Power source circuit malfunction

Motor generator control system

P06D61C

Generator Control Module Offset Power Circuit Voltage Out of Range

P06B01C

Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range

Communication system malfunction

Hybrid control system

P312387

Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message

Sensor and actuator circuit malfunction

Hybrid control system

P0AD911

Hybrid/EV Battery Positive Contactor Circuit Short to Ground

P0AD915

Hybrid/EV Battery Positive Contactor Circuit Short to Auxiliary Battery or Open

P0ADD11

Hybrid/EV Battery Negative Contactor Circuit Short to Ground

P0ADD15

Hybrid/EV Battery Negative Contactor Circuit Short to Auxiliary Battery or Open

P0AE411

Hybrid/EV Battery Precharge Contactor Circuit Short to Ground

P0AE415

Hybrid/EV Battery Precharge Contactor Circuit Short to Auxiliary Battery or Open

Motor generator control system

P0A3F16

Drive Motor "A" Position Sensor Circuit Voltage Below Threshold

P0A4B16

Generator Position Sensor Circuit Voltage Below Threshold

P0A4B21

Generator Position Sensor Signal Amplitude < Minimum

P0A4B22

Generator Position Sensor Signal Amplitude > Maximum

P0C5013

Drive Motor "A" Position Sensor Circuit "A" Circuit Open

P0C5016

Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold

P0C5017

Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold

P0C5A13

Drive Motor "A" Position Sensor Circuit "B" Circuit Open

P0C5A16

Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold

P0C5A17

Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold

P0C6413

Generator Position Sensor Circuit "A" Circuit Open

P0C6416

Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold

P0C6417

Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold

P0C6913

Generator Position Sensor Circuit "B" Circuit Open

P0C6916

Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold

P0C6917

Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold

System malfunction

Hybrid control system

P0D2D1C

Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range

P1C8349

High Voltage Power Resource Circuit Voltage Sensor after Boosting Malfunction

Motor generator control system

P0D2D16

Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold

P0D2D17

Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold

P1CB69E

Drive Motor "A" Inverter Voltage Sensor (VH) Stuck On

HINT:

  • P0C7600 may be output as a result of the malfunction indicated by the DTCs above.
    1. The chart above is listed in inspection order of priority.
    2. Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)

(e) Turn the power switch off.

B

GO TO DTC CHART (HYBRID CONTROL SYSTEM)

C

GO TO DTC CHART (MOTOR GENERATOR CONTROL SYSTEM)

A

2.

CHECK SHUT DOWN SIGNAL CIRCUIT

Click here

HINT:

If the "Shut Down Signal Circuit" inspection results are normal, perform the next step.

NEXT

REPLACE INVERTER WITH CONVERTER ASSEMBLY

    Motor Electronics Coolant Pump "A" Component Internal Failure (P0C7396)

    Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range (P0D2D1C)

    See More:

    Toyota Avalon Service & Repair Manual > Brake Booster(for Gasoline Model): Removal
    REMOVAL CAUTION / NOTICE / HINT The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed and installed, or replaced during brake booster assembly removal/installation are shown below. Necessary Procedures After Parts Removed/In ...

    Toyota Avalon Owners Manual

    Toyota Avalon Service & Repair Manual

    © 2024 Copyright www.tavalon.net
    0.0179