Toyota Avalon Service & Repair Manual: Roof Drip Side Finish Moulding

Components

COMPONENTS

ILLUSTRATION

*1

CENTER ROOF DRIP SIDE FINISH MOULDING

*2

NO. 1 ROOF DRIP SIDE FINISH MOULDING CLIP

Non-reusable part

-

-

Installation

INSTALLATION

CAUTION / NOTICE / HINT

HINT:

  • Use the same procedure for the RH side and LH side.
  • The following procedure is for the LH side.

PROCEDURE

1. INSTALL NO. 1 ROOF DRIP SIDE FINISH MOULDING CLIP

NOTICE:

When installing new No. 1 roof drip side finish moulding clips, remove any double-sided tape remaining where the No. 1 roof drip side finish moulding clips will be installed on the vehicle body and clean the vehicle body with a non-residue solvent.

(a) Apply a 2 to 3 mm (0.0787 to 0.118 in.) bead of adhesive (3M DP-105 or equivalent) to each new No. 1 roof drip side finish moulding clip.

HINT:

Adhesive strength (tensile strength): 13.7 MPa (140.0 kgf/cm2, 1987 psi) or more (when the temperature is 23°C (73°F).)

*a

Adhesive

*b

2 to 3 mm Bead of Adhesive

(b) Install the 2 No. 1 roof drip side finish moulding clips to the positions on the roof panel shown in the illustration. Determine the locations and firmly press and install the 2 No. 1 roof drip side finish moulding clips.

Standard Measurement:

Area

Measurement

Area

Measurement

A

4.5 to 5.5 mm (0.177 to 0.217 in.)

B

1.1 to 2.1 mm (0.0433 to 0.0827 in.)

C

4.6 mm (0.181 in.)

D

5.0 mm (0.197 in.)

E

4.5 to 5.5 mm (0.177 to 0.217 in.)

F

1.9 mm (0.0748 in.)

G

1.5 to 2.5 mm (0.0591 to 0.0984 in.)

-

-

(c) Wait at least 40 minutes before installing the center roof drip side finish moulding.

HINT:

  • Initial hardening time: 40 minutes
  • Complete hardening time: 24 hours

2. INSTALL CENTER ROOF DRIP SIDE FINISH MOULDING

(a) Engage the 2 clips to install the center roof drip side finish moulding as shown in the illustration.

Removal

REMOVAL

CAUTION / NOTICE / HINT

HINT:

  • Use the same procedure for the RH side and LH side.
  • The following procedure is for the LH side.

PROCEDURE

1. REMOVE CENTER ROOF DRIP SIDE FINISH MOULDING

(a) Apply protective tape around the center roof drip side finish moulding as shown in the illustration.

Protective Tape

-

-

(b) Using a moulding remover, disengage the 2 clips and remove the center roof drip side finish moulding.

NOTICE:

  • Do not remove the No. 1 roof drip side finish moulding clips.
  • If a No. 1 roof drip side finish moulding clip is damaged or falls off, replace it with a new one.
    Rocker Panel Moulding

    Windshield Outside Moulding

    See More:

    Toyota Avalon Service & Repair Manual > Lighting (ext): High Mounted Stop Light Assembly
    ComponentsCOMPONENTS ILLUSTRATION *1 CENTER STOP LIGHT SET - - InspectionINSPECTION PROCEDURE 1. INSPECT CENTER STOP LIGHT SET *a Component without harness connected (Center Stop Light Set) (a) Apply auxiliary battery voltage to the center stop light set and check that the light illuminates. OK: Me ...

    Toyota Avalon Owners Manual

    Toyota Avalon Service & Repair Manual

    © 2024 Copyright www.tavalon.net
    0.0126