Toyota Avalon (XX50) 2019-2022 Service & Repair Manual: Inspection

INSPECTION

PROCEDURE

1. INSPECT NO. 1 COOLER THERMISTOR

(a) Measure the resistance according to the value(s) in the table below.

*a

Component without harness connected

(No. 1 Cooler Thermistor)

*b

Sensing Portion

*c

Resistance (kΩ)

*d

Temperature (°C (°F))

*e

Allowable Range

-

-

Standard Resistance:

Tester Connection

Condition

Specified Condition

1 - 2

-10°C (14°F)

7.30 to 9.10 kΩ

-5°C (23°F)

5.65 to 6.95 kΩ

0°C (32°F)

4.40 to 5.35 kΩ

5°C (41°F)

3.40 to 4.15 kΩ

10°C (50°F)

2.70 to 3.25 kΩ

15°C (59°F)

2.14 to 2.58 kΩ

20°C (68°F)

1.71 to 2.05 kΩ

25°C (77°F)

1.38 to 1.64 kΩ

30°C (86°F)

1.11 to 1.32 kΩ

If the resistance is not as specified, replace the No. 1 cooler thermistor.

NOTICE:

  • Hold the sensor only by its connector. Touching the sensing portion may change the resistance value.
  • When measuring, the sensor temperature must be the same as the ambient temperature.

HINT:

As the temperature increases, the resistance decreases (see the graph).

    Components

    Installation

    See More:

    Toyota Avalon (XX50) 2019-2022 Service & Repair Manual > Wireless Charging System(for Gasoline Model): Problem Symptoms Table
    PROBLEM SYMPTOMS TABLE HINT: Use the table below to help determine the cause of problem symptoms. If multiple suspected areas are listed, the potential causes of the symptoms are listed in order of probability in the "Suspected Area" column of the table. Check each symptom by checking the suspected ...

    Toyota Avalon (XX50) 2019-2022 Owners Manual

    Toyota Avalon (XX50) 2019-2022 Service & Repair Manual

    © 2024 Copyright www.tavalon.net
    0.0262